Expiratory muscle weakness quantified by maximal expiratory pressure may be insufficient in predicting critical outcomes in mechanically ventilated patients
2020
Détails
Titre
Expiratory muscle weakness quantified by maximal expiratory pressure may be insufficient in predicting critical outcomes in mechanically ventilated patients
Auteur(s)/ trice(s)
Combret, Yann (Groupe Hospitalier du Havre, Le Havre, France)
Prieur, Guillaume (Groupe Hospitalier du Havre, Le Havre, France)
Gravier, Francis-Edouard (ADIR Association, Rouen, France)
Bonnevie, Tristant (ADIR Association, Rouen, France)
Contal, Olivier (HESAV Haute Ecole de Santé Vaud, HES-SO Haute école spécialisée de Suisse occidentale)
Lamia, Bouchra (Groupe Hospitalier du Havre, Le Havre, France)
Medrinal, Clément (Groupe Hospitalier du Havre, Le Havre, France)
Prieur, Guillaume (Groupe Hospitalier du Havre, Le Havre, France)
Gravier, Francis-Edouard (ADIR Association, Rouen, France)
Bonnevie, Tristant (ADIR Association, Rouen, France)
Contal, Olivier (HESAV Haute Ecole de Santé Vaud, HES-SO Haute école spécialisée de Suisse occidentale)
Lamia, Bouchra (Groupe Hospitalier du Havre, Le Havre, France)
Medrinal, Clément (Groupe Hospitalier du Havre, Le Havre, France)
Date
2020-02
Publié dans
Annals of intensive care
Volume
February 2020, vol. 10, suppl. 1, art. 16 (COK-11)
Pagination
1 p.
ISSN
2110-5820
Type d'article
scientifique
Domaine
Santé
Filière
Physiothérapie
Ecole
HESAV
Institut
Unité de recherche en santé, HESAV
Note
Proceedings of Réanimation 2020, the French Intensive Care Society International Congress
Le document apparaît dans
Articles scientifiques
Global